Sorry for not appearing online more often. I keep reminding myself of the need to write about the new connecting technologies. This time I can't ignore it.
Transportable clean energy plant is the bridge between the current centralized grid - someone called it "the biggest machine ever built by humankind" - to a decentralized distributed efficient energy generation. More often than anything else the subject is electrical power.
However, where thermal energy is needed - from heating to cooling and hot water for domestic or commercial needs - it can be produced much more efficiently bypassing the conversion to and from electricity. Modern solar thermal systems combined with state-of the art thermal storage and/or auxiliary source (small heat pump or other) cam provide 4-5 times more thermal energy than PV -based system of the similar size could. Connecting them in the Integrated Energy Module would result in the best of both worlds and could be made in a size of a small trailer.
Connecting new technologies and future vision in adaptable System Architecture
Showing posts with label heat pumps. Show all posts
Showing posts with label heat pumps. Show all posts
Tuesday, June 7, 2016
Wednesday, May 6, 2015
Tesla Powerwall a Breakthrough?
In a Steve Jobs style presentation Elon Musk announced a "revolution" in energy storage - Tesla's Powerwall.
The part about the day-night gap between demand and supply of solar energy is very similar to what I discuss in my presentations. Ascent Systems Technologies addresses it differently however. It uses vacuum tube solar thermal collectors which are more efficient then even the best PV modules, a thermal storage as a battery, and an air-to-water heat pump as a booster. The resulting integrated system is much more cost-effective comparing to a PV-battery system.
There is no
question about the need of efficient, affordable and reliable batteries.
Is his Powerwall a breakthrough? I don't know, time will tell. At least
it is a push.
The following is an extract from Bloomberg:
The new Tesla Powerwall home batteries come in two sizes - 7 and 10 kWh - but the differences extend beyond capacity to the
chemistry of the batteries. The 7kWh version is made for daily use,
while its larger counterpart is only intended to be used as occasional
backup when the electricity goes out. The bigger Tesla battery isn't
designed to go through more than about 50 charging cycles a year...
Here’s where things get interesting. SolarCity, with Musk as its
chairman, has decided not to install the 7kWh Powerwall that’s optimized
for daily use. Bass said that battery "doesn't really make financial
sense"...
But if its sole purpose is to provide backup power to a home, the juice
it offers is but a sip. The model puts out just 2 kilowatts of
continuous power, which could be pretty much maxed out by a single
vacuum cleaner, hair drier, microwave oven or a clothes iron. The
battery isn’t powerful enough to operate a pair of space heaters; an
entire home facing a winter power outage would need much more..
But I would also be interested to know what kind of
battery it is: lithium-ion or some other, Musk didn't mention it in his presentation. What is weight, and what are the dimensions? Do they
require rare elements and their manufacturing is highly energy consuming
as most of them? If yes, then their environmental benefits might be
questionable.
The part about the day-night gap between demand and supply of solar energy is very similar to what I discuss in my presentations. Ascent Systems Technologies addresses it differently however. It uses vacuum tube solar thermal collectors which are more efficient then even the best PV modules, a thermal storage as a battery, and an air-to-water heat pump as a booster. The resulting integrated system is much more cost-effective comparing to a PV-battery system.
Friday, December 5, 2014
QUEST 2014
Back from Vancouver where attended QUEST 2014 Conference and Trade Show. I will share more when process all the information which was a lot. Here are some of the impressions from the conference.
Tuesday, September 30, 2014
Bullitt Centre - Connecting technologies and 90 percent rule
Another example of connecting technologies - Bullitt Centre in Seattle - has been called the world’s greenest office building.
To make enough room for 14,000 square feet array of solar panels the roof had to be made projected as much as 20 feet beyond the building's perimeter. According to the designers, the solar array delivers 242 kilowatts of power in total. In the summer, it will produce more electricity than it uses, and in the winter it will produce less. The surplus power will be sold into the Seattle electric grid. The building then draws electricity from the grid in the winter months when production is low. To achieve its “net zero energy” goal, the summer production surplus must meet or exceed the winter production deficit. While strictly speaking it is not a 100% efficiency, this is a way around the 90 percent barrier.
Thursday, January 30, 2014
AST begins work on the Integrated Thermal Hydronic Module
Ascent Systems Technologies (AST) received an Engage grant from the Natural Sciences and Engineering Research Council of Canada (NSERC) to work on the collaborative project with the University of British Columbia (UBC) in Vancouver with the purpose of developing an adaptive control system for Integrated Thermal Hydronic Module (ITHM). The project includes setting up a pilot system configuration at the Centre for Interactive Research on Sustainability (CIRS) at UBC.
The architecture of the system utilizes principles of modularity and scalability, and it is optimized using the ASPA predictive algorithm developed by AST with support from the National Research Council of Canada (NRC).
The system automatically maintains its parameters within the predetermined range while responding to the actual demand of energy by implementing an adaptive control algorithm with the real-time feedback loop. Some of the distinct features of ITHM are:
- The system needs very little power to operate, making it a perfect candidate for off-grid applications.
- The system can be configured in a compact package such that it can be implemented on a mobile platform.
- The system can be scaled up for increased capacity by combining several modules in an array.
- The system is digitally controlled with embedded network capability allowing for remote monitoring and data processing.
The architecture of the system utilizes principles of modularity and scalability, and it is optimized using the ASPA predictive algorithm developed by AST with support from the National Research Council of Canada (NRC).
The system automatically maintains its parameters within the predetermined range while responding to the actual demand of energy by implementing an adaptive control algorithm with the real-time feedback loop. Some of the distinct features of ITHM are:
- The system needs very little power to operate, making it a perfect candidate for off-grid applications.
- The system can be configured in a compact package such that it can be implemented on a mobile platform.
- The system can be scaled up for increased capacity by combining several modules in an array.
- The system is digitally controlled with embedded network capability allowing for remote monitoring and data processing.
Labels:
CIRS,
clean energy,
control,
Evolving Technologies,
heat pumps,
ITHM,
modularity,
Network,
solar thermal,
Sustainable development,
Sustainable Network,
Systems Architecture,
UBC
Tuesday, October 8, 2013
Connecting Technologies - Part 2: Aero-Solar System
In the previous post we talked about how connecting technologies can create a new quality on the example of a turbofan engine which made possible modern commercial aviation.
I dare to claim that the same is just about going to happen with integrated building energy technology.
Let's look for example at today's solar thermal systems. Electromagnetic energy of solar radiation is captured by solar collectors, transformed into thermal energy of the heated core, and passed to the domestic hot water system via heat exchanger. The pump circulates the water in the system passing this thermal energy to the storage.
It would be nice if the sun would never set and we could collect its "free" energy 24 hours a day. As we all know, this is not the case. The stubborn sun doesn't want to shine all day. Worse even, it circles across the sky, it rises and sets at different time in winter and summer, not even talking about clouds and other nature phenomena, making it not possible to consistently collect energy during the day. At the best, we can count on taking the most of it but for one brief moment when the sun is directly above the collector (and even then, only if we tilt it at the right angle - which is a subject of a separate discussion). Therefore the energy we can in theory collect during the day would have a profile something like the one shown here in dotted line. In practice, due to the delayed heat loss it might be something like a solid orange line.
However, what if the actual demand for hot water is not when we have the most energy available?
And indeed the typical household hot water demand is almost inverted to the energy profile. In the morning we wake up, take a shower, make breakfast and go to work. There is a morning spike in hot water consumption. We usually not home during the day - at work, at school and other business - thus the consumption through mid-day is near-zero. Then we come home, we have a dinner, we turn on the dishwasher machine, we do laundry, take a bath - another, larger spike in hot water consumption.
Comparing both graphs, one can easily see that peaks of one correspond to the troughs of another! Classical economics question: how to match supply and demand?
One solution is to accumulate the excess energy when we have the peak of its availability and use it when we don't have enough, say in the evening. Sure, a hot water storage tank may do the work. This is what is used in almost all domestic hot water systems, regardless of the source of energy, either conventional gas or electric heater or alternative, like solar or geothermal. Speaking of the latter, this can be a consistent source of energy (shown in the solid black line on the previous graph), since the temperature under ground does not depend on the sun position or the weather - a couple of meters down from the surface it is practically constant throughout the year. The problem is in order to obtain enough energy, it requires drilling, which is often not possible in the urban conditions, sometimes not allowed for environmental reasons and is always expensive.
Back to solar. Many locations in Canada enjoy abundance of solar radiation, especially in summer.
Solar thermal system, on average, is the most cost-effective renewable system. It provides much higher efficiency than solar photovoltaic systems (the latter involves conversion of solar radiation into electrical energy, and any conversion means a loss of efficiency). It would not come as a surprise however, that due to shorter days and lower sun, the energy coming from sun in winter is much less than in summer. If we want to match the summer peak demand, an example of this kind of energy balance over 12 months might look something like the graph below.
But we also want to take shower in winter - may be even more than in summer! How we should always match the demand? Of course, we can add more solar collectors, increasing the total energy collected to the point when we match the peak demand in the worst winter time. Then the energy balance may look something like on the next graph.
One can easily see that even if we manage to match the peak demand for any given moment, for the most part we collect much more energy than we are able to use, so we will need to dissipate (dump) it. Overcapacity is not a very sustainable way of building sustainable system, is it? Not even talking about additional cost for extra-collectors and, in most cases, simply impossibility to allocate a large enough area which would be required to accommodate that many collectors.
We want to size the solar thermal system in such a way so to collect energy when we have an excess of it comparing to the demand to be stored and used when there will be lack (or absence) of the usable solar radiation. But how to choose the right storage capacity?
A high-capacity thermal storage capable to accumulate large amount of thermal energy and be efficient enough not to loose it quickly, may require a large super insulated tank, ideally underground, which may be impractical or otherwise expensive.
The answer comes again in the form of integrated system. Air-to-water heat pumps (a.k.a. active thermal exchange) are becoming more and more efficient reaching COP 5-6 and more, meaning they can generate 5-6 times more energy than they consume. Combined with the solar thermal collector and high-capacity and low-loss thermal storage, controlled by the program using adaptive algorithm, this integrated system can satisfy demand at any time cost effectively, with high reliability, requiring little physical space, and using no fossil fuel.
Ascent Systems Technologies, with support from National Research Council of Canada, has developed a program called ASPA (Aero-Solar Predictive Algorithm). It does exactly that - automatically chooses the most optimal parameters of the integrated hydronic system given the location and the actual demand.
Sunday, September 15, 2013
Performance Home, Part 2
Picture a hole in the side of your house
that’s just as a big as a typical computer screen. Imagine the
wind blowing through that hole. The hole is real. If you were to combine all the cracks and crannies
in a typical Canadian home, they’d add up to almost 1,400 square
centimetres, roughly the size of 2.5 magazine pages.
Plugging that hole is the simplest way for Canada to save energy. Plugging the hole also saves money, creates jobs, cuts greenhouse-gas emissions and makes our homes more comfortable.
Yet despite the fact that buildings account for roughly one-third of our national energy consumption and the fact that we’re world leaders in small building energy-conservation technology, Canadians still haven’t plugged the hole. Most of our existing homes remain quite drafty, and most of our new homes fail to meet decades-old efficiency standards.
Builders have long known that heat claims the lion’s share of the energy consumed in Canadian homes: 57% of the total, compared with 24% for hot water, 13% for appliances and 5% for lighting. They’ve also known that heat escapes wherever air escapes, mostly under doors and around windows.
A standard measurement agreed upon is: the number of times per hour the blowerdoor fan would suck all the air out of a house at a prescribed pressure of 50 pascals (Pa). The metric is called “air changes per hour (ACH)” at 50 Pa. With gaps totaling 1,400 sq. cm, the average Canadian home leaks enough air to result in 6.85 ACH@50Pa.
In the wake of the 1973 Arab oil embargo, the Saskatchewan Research Council designed an energy-efficient home appropriate for the Saskatchewan winter. The oil crisis prompted many similar projects, with most focusing on new ways to trap solar heat within a more or less standard building. The Saskatchewan team elected, instead, to design a radically more efficient building envelope. The Saskatchewan Conservation House, completed in Regina in 1977, was likely one of the first buildings to combine three key elements: superinsulation, extreme airtightness and a heat-recovery ventilator.
In an era when nearly all houses were constructed of four-inch-thick walls filled with R-8 insulation, the two-storey Saskatchewan house featured 12-inch-thick R-40 walls and R-60 roof insulation. Likewise, single-paned windows were then the norm; this home had triple-glazed windows. The house also boasted extreme airtightness. Most new houses at the time scored in the range of 9 ACH@50Pa; the SCH achieved 0.8 ACH@50Pa. At the time it was likely the tightest house in the world.
To provide fresh air to the airtight house, the Saskatchewan team built an air-to-air heat exchanger. This device pulled in fresh (but cold) outdoor air through a series of baffles. Stale (but warm) indoor air was pushed out through the other side of those same baffles, and heat was transferred from the exhaust air to the incoming fresh air.
The SCH had no furnace. Instead, it relied on a system that collected solar heat during the day, stored it in a water tank, then released the heat at night. All told, the house required less than a quarter of the energy consumed by a standard home of the time.
That same year, the “House As a System” approach pioneered in Saskatchewan formed the basis for a new national building standard that required R-20 insulation, blower-door test results of 1.5 ACH@50Pa or better, the installation of a heat-recovery ventilator and the use of non-toxic materials. The new standard became a partnership between NRCan and the Canadian Home Builders’ Association. It was the toughest standard in the world at that time and presaged by decades the advent of green building initiatives such as BuiltGreen or LEED (Leadership in Energy and Environmental Design). The new standard was voluntary, but its authors intended for its gradual integration into the national building code. With their sights set on plugging the hole in Canadian homes by the turn of the century, they named the new standard “R-2000.”
The above content is mostly a shortened re-print of the article High-Performance Homes - Why isn't Canada spearheading the movement to build more sustainable homes? published in June 2012 issue of Canadian Geographic.
Plugging that hole is the simplest way for Canada to save energy. Plugging the hole also saves money, creates jobs, cuts greenhouse-gas emissions and makes our homes more comfortable.
We know how to find the hole. Canadians pioneered the use of a tool
that can measure the airtightness of a building. Natural Resources
Canada (NRCan) has used this “blower door” to test more than 800,000
Canadian homes.
Canadians also know how to fix the hole. Way back in 1977, they built a house
so airtight and so well insulated that a hair dryer could have kept it
warm through the winter – in cold Saskatchewan.Yet despite the fact that buildings account for roughly one-third of our national energy consumption and the fact that we’re world leaders in small building energy-conservation technology, Canadians still haven’t plugged the hole. Most of our existing homes remain quite drafty, and most of our new homes fail to meet decades-old efficiency standards.
Builders have long known that heat claims the lion’s share of the energy consumed in Canadian homes: 57% of the total, compared with 24% for hot water, 13% for appliances and 5% for lighting. They’ve also known that heat escapes wherever air escapes, mostly under doors and around windows.
A standard measurement agreed upon is: the number of times per hour the blowerdoor fan would suck all the air out of a house at a prescribed pressure of 50 pascals (Pa). The metric is called “air changes per hour (ACH)” at 50 Pa. With gaps totaling 1,400 sq. cm, the average Canadian home leaks enough air to result in 6.85 ACH@50Pa.
In the wake of the 1973 Arab oil embargo, the Saskatchewan Research Council designed an energy-efficient home appropriate for the Saskatchewan winter. The oil crisis prompted many similar projects, with most focusing on new ways to trap solar heat within a more or less standard building. The Saskatchewan team elected, instead, to design a radically more efficient building envelope. The Saskatchewan Conservation House, completed in Regina in 1977, was likely one of the first buildings to combine three key elements: superinsulation, extreme airtightness and a heat-recovery ventilator.
In an era when nearly all houses were constructed of four-inch-thick walls filled with R-8 insulation, the two-storey Saskatchewan house featured 12-inch-thick R-40 walls and R-60 roof insulation. Likewise, single-paned windows were then the norm; this home had triple-glazed windows. The house also boasted extreme airtightness. Most new houses at the time scored in the range of 9 ACH@50Pa; the SCH achieved 0.8 ACH@50Pa. At the time it was likely the tightest house in the world.
To provide fresh air to the airtight house, the Saskatchewan team built an air-to-air heat exchanger. This device pulled in fresh (but cold) outdoor air through a series of baffles. Stale (but warm) indoor air was pushed out through the other side of those same baffles, and heat was transferred from the exhaust air to the incoming fresh air.
The SCH had no furnace. Instead, it relied on a system that collected solar heat during the day, stored it in a water tank, then released the heat at night. All told, the house required less than a quarter of the energy consumed by a standard home of the time.
That same year, the “House As a System” approach pioneered in Saskatchewan formed the basis for a new national building standard that required R-20 insulation, blower-door test results of 1.5 ACH@50Pa or better, the installation of a heat-recovery ventilator and the use of non-toxic materials. The new standard became a partnership between NRCan and the Canadian Home Builders’ Association. It was the toughest standard in the world at that time and presaged by decades the advent of green building initiatives such as BuiltGreen or LEED (Leadership in Energy and Environmental Design). The new standard was voluntary, but its authors intended for its gradual integration into the national building code. With their sights set on plugging the hole in Canadian homes by the turn of the century, they named the new standard “R-2000.”
The above content is mostly a shortened re-print of the article High-Performance Homes - Why isn't Canada spearheading the movement to build more sustainable homes? published in June 2012 issue of Canadian Geographic.
Monday, December 24, 2012
ASPA News
National Research Council of Canada has approved Aero-Solar Predictive Algorithm (ASPA) Validation Project for funding through the Industrial Research Assistance Program.
Center for Interactive Research on Sustainability at University of British Columbia in Vancouver and Ascent Systems Technologies has agreed in principle on the concept of mutual cooperation. CIRS will provide their energy consumption and production data for testing ASPA against it. Ascent Systems will provide results to CIRS for analysis and further system optimization consideration.
ASPA is designed utilizing principles of Systems Architecture. The first build of the ASPA software has been transferred to a relational database, providing ease of access, flexibility and scalability.
Center for Interactive Research on Sustainability at University of British Columbia in Vancouver and Ascent Systems Technologies has agreed in principle on the concept of mutual cooperation. CIRS will provide their energy consumption and production data for testing ASPA against it. Ascent Systems will provide results to CIRS for analysis and further system optimization consideration.
ASPA is designed utilizing principles of Systems Architecture. The first build of the ASPA software has been transferred to a relational database, providing ease of access, flexibility and scalability.
Monday, July 9, 2012
Sun Peaks Fire Hall Sustainable Energy upgrade - Day One
Today we have installed the air-source reversible high efficiency thermo-exchange system on the Sun Peaks Fire Hall office building. In time for the heat wave, the office will be now nice and cool (while warm in winter).
Features:
Features:
- 1 Daikin multi-split system model 2MXS18
- 2 indoor units CTX07, CTX12
- SEER 19.5 (effective 22-26)
- COP = 3.4 or greater @ 47F
- Slim duct to cover outdoor lines for aesthetically pleasing appearance
- Higher heating/cooling capacity at lower temperatures than other brands
- Intelligent eye function, which delivers up to 30% additional savings in energy usage
Saturday, July 7, 2012
Sun Peaks Fire Hall Sustainable Energy upgrade
Sun Peaks Resort Municipality makes the first step toward the efficient and sustainable energy use.
Monday July 9, 2012 the work begins on the first phase of the Sun Peaks Fire Hall facility upgrade. It involves upgrade of the office building with the state-of-the-art high-efficiency air-to-air system, which can work in reversible mode. It provides heating in winter and cooling in summer consuming up to 3 times less electricity than currently used electrical baseboard heaters and conventional wall-mounted air-conditioning units. Automatically maintaining comfortable temperature and performing constant air circulation, the system provides a healthy environment in the building. The "intelligent eye" feature of the system reduces the level of heating or cooling when no occupancy detected in the building, and automatically brings it back to the preset level when the occupancy is detected.
The next part of the planned upgrade is installation of the solar thermal system to provide hot water needs for the facility. It will include space-age vacuum tube efficient solar UV collector technology which will practically eliminate the need for the electric boiler, which will be kept as a back-up only.
Stay tuned for further updates !
Monday July 9, 2012 the work begins on the first phase of the Sun Peaks Fire Hall facility upgrade. It involves upgrade of the office building with the state-of-the-art high-efficiency air-to-air system, which can work in reversible mode. It provides heating in winter and cooling in summer consuming up to 3 times less electricity than currently used electrical baseboard heaters and conventional wall-mounted air-conditioning units. Automatically maintaining comfortable temperature and performing constant air circulation, the system provides a healthy environment in the building. The "intelligent eye" feature of the system reduces the level of heating or cooling when no occupancy detected in the building, and automatically brings it back to the preset level when the occupancy is detected.
The next part of the planned upgrade is installation of the solar thermal system to provide hot water needs for the facility. It will include space-age vacuum tube efficient solar UV collector technology which will practically eliminate the need for the electric boiler, which will be kept as a back-up only.
Stay tuned for further updates !
Sunday, March 18, 2012
A2W
Did I say all manufacturers are Japanese ? Well, not exactly. The French company CIAT has designed a high-temperature heat pump (65°C hot water) that would efficiently replace conventional boilers down to -20C: Aqualis Caleo
Sunday, November 20, 2011
Air Heat Pump performance
As part of the sustainability efforts in general, and the energy-efficiency upgrade proposal for Sun Peaks fire hall in particular, I was trying to find the performance of the split systems we have chosen for that upgrade under low temperatures, which are common here. Not being able to find this information readily available, I contacted Daikin directly and was pleasantly surprised by their prompt response and their providing me with all the information I asked, and even more, including complete Engineering Reports on their units. As a result, I was able to chart these graphs, which give visual indication of the COP vs. outside temperature performance.
The first one is multi-split MSX18, the second is commercial VRV-III-S. Both graphs are for the 20C indoor temperature. They show that, although decreasing, the performance is still high enough to supply heat even at -15C and probably down to -20C. When indoor temperature can be allowed to be lower (like in the example of the garage for fire trucks), or if it can be supplemented with back-up source (e.g. infrared radiant heaters), the performance will be dropping even slower, remaining at or above 2.5 COP even under -20C.